Availability and access to clean water to all is Goal No.6 of the UN Sustainable Development Goals. Measuring the availability and the biophysical properties of water in rural areas is a significant challenge for developing countries like El Salvador.

Tasajera Tides along with the local Multi-Sector Committee identified that drinking water has become an important concern to the community. In Tasajera, there is no potable water system, and people mostly drink underground water, either through a well or an electric pump. Data on well water samples is largely non-existent in the community, and some measurements that exist are not scientifically legitimate. However, Tasajera Tides was able to get a study of local well water from Luis Recio, a Spanish scientist working in El Salvador in collaboration with the University of Alcala de Henares, Sol de Tasajera, and CORDES Foundation.

In this study, Recio took samples of 3 locations of the community covering different distances from the estuarine shore. The samples were taken to a government certified laboratory and tested for microbiologic, physiochemical, and metallic properties. Recio noted that one limitation of this assessment is that it did not test samples for agrichemicals, which is a reasonable observation given the intensive cotton plantations that were managed in Tasajera in the past.

Figure 1.This map shows the 3 sample locations in the Tasajera community.

Conclusions:

The water study provides data that indicates the existence of pollutants and contaminants in the samples collected. Sample 2 showed high levels of nitrates, and sample 3 showed high levels of salinity and microbiologic contamination. The author concluded that awareness campaigns needed to be executed to educate the community of the risks.

Data:

Water Sample 1

IndicatorsReferenceResultMaximum allowed limit*
pH**Standard Methods 19th Edition 4500 H B7.846.0-8.5
OlorStandard Methods 19th Edition 2150 BNRNR
Color verdaderoStandard Methods 19th Edition 2120 B0 mg/L15
Turbidez**Standard Methods 19th Edition 2130 B<0.07 UNT5***
TemperaturaStandard Methods 19th Edition 2550 B27ºCNR
Sólidos Totales Disueltos**Standard Methods 19th Edition 2540 C203.00 mg/L1000
Hierro Total** (Fe)Standard Methods 19th Edition 3500 Fe 3111B<0.02 mg/L0.30
Manganeso** (Mn)Standard Methods 19th Edition 3500 Mn 3111B<0.020.1
Dureza Total** (CaCO3)Standard Methods 19th Edition 2340 C92.00 mg/L500
Sulfatos (SO4)Método desarrollado y validado por el Laboratorio de Control de Calidad de Alimentos y Aguas. Basado en Standard Methods 19th Edition 4500-SO42-F12.18 mg/L400.00
Nitratos** (NO3)Standard Methods 19th Edition 4500 NO3 B30.86 mg/L45.00
Fluoruros (F)Standard Methods 19th Edition 4500 F D<0.20 mg/L1.00
Cloro residualStandard Methods 19th Edition 4500 Cl G0.0 mg/L0.3-1.1
Water Sample 2:
IndicatorsReferenceResultMaximum allowed limit*
pH**Standard Methods 19th Edition 4500 H B7.656.0-8.5
OlorStandard Methods 19th Edition 2150 BNRNR
Color verdaderoStandard Methods 19th Edition 2120 B0 mg/L15
Turbidez**Standard Methods 19th Edition 2130 B<0.07 UNT5***
TemperaturaStandard Methods 19th Edition 2550 B27ºCNR
Sólidos Totales Disueltos**Standard Methods 19th Edition 2540 C495.50 mg/L1000
Hierro Total** (Fe)Standard Methods 19th Edition 3500 Fe 3111B<0.020.30
Manganeso** (Mn)Standard Methods 19th Edition 3500 Mn 3111B0.18 mg/L0.1
Dureza Total** (CaCO3)Standard Methods 19th Edition 2340 C244.00 mg/L500
Sulfatos (SO4)Método desarrollado y validado por el Laboratorio de Control de Calidad de Alimentos y Aguas. Basado en Standard Methods 19th Edition 4500-SO42-F62.35 mg/L400.00
Nitratos** (NO3)Standard Methods 19th Edition 4500 NO3 B52.92 mg/L45.00
Fluoruros (F)Standard Methods 19th Edition 4500 F D<0.20 mg/L1.00
Cloro residualStandard Methods 19th Edition 4500 Cl G0.0 mg/L0.3-1.1
Water Sample 3:
IndicatorsReferenceResultMaximum allowed limit*
pH**Standard Methods 19th Edition 4500 H B7.226.0-8.5
OlorStandard Methods 19th Edition 2150 BNRNR
Color verdaderoStandard Methods 19th Edition 2120 B0 mg/L15
Turbidez**Standard Methods 19th Edition 2130 B<0.07 mg/L5***
TemperaturaStandard Methods 19th Edition 2550 B27ºCNR
Sólidos Totales Disueltos**Standard Methods 19th Edition 2540 C6,050.00 mg/L1000
Hierro Total** (Fe)Standard Methods 19th Edition 3500 Fe 3111B<0.02 mg/L0.30
Manganeso** (Mn)Standard Methods 19th Edition 3500 Mn 3111B1.51 mg/L0.1
Dureza Total** (CaCO3)Standard Methods 19th Edition 2340 C2350.00 mg/L500
Sulfatos (SO4)Método desarrollado y validado por el Laboratorio de Control de Calidad de Alimentos y Aguas. Basado en Standard Methods 19th Edition 4500-SO42-F303.66 mg/L400.00
Nitratos** (NO3)Standard Methods 19th Edition 4500 NO3 B2.38 mg/L45.00
Fluoruros (F)Standard Methods 19th Edition 4500 F D<0.20 mg/L1.00
Cloro residualStandard Methods 19th Edition 4500 Cl G0.0 mg/L0.3-1.1
*Valor de acuerdo de la Norma Salvadoreña Agua. Agua Potable NSO 13.07.01.08 (Segunda Actualización) **Determinaciones Acreditadas bajo Norma ISO/IEC 17025:2005 ***Para el agua tratada en la salida de planta de tratamiento de aguas superficiales el Límite Máximo permisible es 1.

For download the entire study, click here:Recio 2015
Thanks to Luis Recio, CORDES, for making this study available to Tasajera Tides.

Economy

Economic indicators are essential for securing the long-term sustainability of a community.

Society

The social dimension of a community influences the health and wellbeing of its members.

Environment

Environmental issues have a strong impact on the wellbeing of a community.